Take Free NDT MT Level 2 Exam Practice Test – Quiz Course

NDT Magnetic Particles Testing Level 2 (MT-2) General Examination latest Questions and Answers

1.

Which of the following is not a property of magnetic lines of force?

 
 
 
 

2.

Surrounding an electromagnet, the magnetic field is strongest:

 
 
 
 

3.

The value of permeability is:

 
 
 
 

4.

The flux density of the magnetism induced by a coil is affected by:

 
 
 
 

5.

How many turns of a coil will be needed to establish a longitudinal field in a steel shaft that is 22.86 cm (9 inches) long and 7.62 cm (3 inches) in diameter? 3000 amperes magnetizing current is available, it is desired to magnetize the part in accordance with the formula NI = 45,000/(L/D):

 
 
 
 

6.

How many ampere-turns are required to magnetize a part that is 40.6 cm (16 inches) long and 5 cm (2 inches) in diameter?

 
 
 
 

7.

The lines of flux or force in a circularly magnetized ferromagnetic bar:

 
 
 
 

8.

In which magnetizing method is the current passed directly through the part, thereby setting up a magnetic field at right angles to the current flow?

 
 
 
 

9.

Which of the following is false concerning a magnetic field in and around a hollow conductor as compared to that of a solid conductor of the same outside diameter when both are of the same magnetic material, and when the applied current is the same?

 
 
 
 

10.

The field is a section of ferromagnetic pipe being magnetized by means of a central conductor is strongest at the:

 
 
 
 

11.

For a 7.6 cm (3 inches) diameter bar how much current is needed to magnetize the bar for the detection of longitudinal discontinuities:

 
 
 
 

12.

For detection of longitudinal discontinuities a 7.6 cm (3 inches) diameter bar is magnetized in:

 
 
 
 

13.

A bar that is 5 cm (2 inches) by 10 cm (4 inches) by 30.5 cm (12 inches) is being magnetized in the circular direction. About how many amperes are required using the perimeter approach?

 
 
 
 

14.

An advantage of AC is that:

 
 
 
 

15.

When a magnetic field cuts across a crack:

 
 
 
 

16.

A disadvantage of AC current is that it:

 
 
 
 

17.

What causes a leakage field in a steel bar?

 
 
 
 

18.

An indication is a defect under which of the following conditions?

 
 
 
 

19.

Paint will not affect the detection of a crack if:

 
 
 
 

20.

A magnetic particle indication is sharp and very fine; this suggests that the discontinuity is:

 
 
 
 

21.

Among the following, the best type of current for the detection of fatigue cracks is:

 
 
 
 

22.

Continuous magnetization provides the most sensitivity because:

 
 
 
 

23.

The sensitivity of magnetic particle testing is greatest when the discontinuity is:

 
 
 
 

24.

To provide reliability and reproducibility in magnetic particle testing, written procedures should include:

 
 
 
 

25.

The magnetic particles are noticed to bunch in some fillet areas and stand on end on the edge of a part being magnetized. These observations indicate that the:

 
 
 
 

26.

Flux density is a measure of the number of magnetic flux lines perpendicular to an area of cross-section. If a discontinuity is in the plane of the unit area, the strongest magnetic article indication will be formed when the discontinuity is:

 
 
 
 

27.

Prods are being used to magnetize a weld area. When dry powder is dusted on the surface, it is observed that there is no mobility of the particles. What is the most probable reason for this observation?

 
 
 
 

28.

The current from portable high amperage units can be applied to the object using:

 
 
 
 

29.

How can parts be tested to determine if they have been adequately demagnetized?

 
 
 
 

30.

The statement ‘magnetic particle testing can be applied to plated and painted parts.

 
 
 
 

31.

A group of indications, some sharp and some broad and fuzzy, were found on an area of a small forging. Demagnetization and re-inspection eliminated these indications. What was the probable cause?

 
 
 
 

32.

Magnetic particle testing is most likely to find subsurface discontinuities in:

 
 
 
 

33.

Which of the following is not an advantage of Magnetic Particle testing?

 
 
 
 

34.

Which of the following does not represent a limitation of Magnetic Particle testing?

 
 
 
 

35.

The most effective NDT method for locating surface cracks in ferromagnetic materials is:

 
 
 
 

36.

A discontinuity that is produced during solidification of the molten metal is called:

 
 
 
 

37.

The pipe would be classified as what type of discontinuity?

 
 
 
 

38.

A seam would be classified as what type of discontinuity?

 
 
 
 

39.

A lamination in steel plate would be classified as what type of discontinuity?

 
 
 
 

40.

An internal rupture caused by working steel at improper temperatures is called a:

 
 
 
 

41.

Cracks that are caused by alternating stresses above a critical level are called:

 
 
 
 

42.

Cracks that are caused by a combination of tensile stress and corrosion are called:

 
 
 
 

43.

Which of the following are ferromagnetic materials?

 
 
 
 

44.

The reverse magnetizing force necessary to remove a residual magnetic field from a test piece after it has been magnetically saturated is called:

 
 
 
 

45.

Magnetic lines of force enter and leave a magnet at:

 
 
 
 

46.

The ease with which a magnetic field can be established in a test piece is called:

 
 
 
 

47.

Opposition to the establishment of a magnetic field in a test piece is called:

 
 
 
 

48.

The ability of a material to remain magnetic after the magnetizing force is removed is called:

 
 
 
 

49.

A magnetic field that is contained completely within the test piece is called a:

 
 
 
 

50.

Which of the following produces a circular field?

 
 
 
 

51.

A technique used to find transverse discontinuities at the ends of longitudinally magnetized bars by the use of transient currents is called:

 
 
 
 

52.

A leakage field is strongest when a discontinuity interrupts the magnetic flux lines at an angle of:

 
 
 
 

53.

The best method of inducing a circular field in a tube is by a:

 
 
 
 

54.

Magnetic flux density is zero at:

 
 
 
 

55.

Magnetic flux density is highest at:

 
 
 
 

56.

An important consideration when using a direct contact method is:

 
 
 
 

57.

A prod method would be most sensitive to cracks:

 
 
 
 

58.

When using prods, arc burns may be caused by which of the following?

 
 
 
 

59.

The most common source of DC current for magnetic particle testing is:

 
 
 
 

60.

Fields generated in ferromagnetic material with AC current are useful for locating:

 
 
 
 

61.

A common rule of thumb to use for current required in circular magnetisation:

 
 
 
 

62.

The formula, NI = 45000/(L/D), is used to calculate the proper magnetising current for:

 
 
 
 

63.

The formula, NI = 45000/(L/D), gives proper magnetizing current for a coil, regardless of coil size as long as:

 
 
 
 

64.

For direct contact magnetizing methods, the magnetic field is oriented in what direction relative to the current direction?

 
 
 
 

65.

For direct contact magnetizing methods, the current should be flowing in what direction relative to expected discontinuities?

 
 
 
 

66.

What is the magnetic field strength at the surface of a 100 mm diameter bar as compared to that at the surface of a 50 mm diameter bar, each carrying 1000 amps of current?

 
 
 
 

67.

What is the magnetic field strength at the surface of a 25 mm diameter bar as compared to that at the surface of a 50 mm diameter bar, each carrying 1000 amps of current?

 
 
 
 

68.

Magnetic Particles Testing Level 2 (MT-2) Specific Examination
Demagnetization, ASTM E709-95 recommends a coil of ampere-turns:

 
 
 
 

69.

According to ASTM E709-95 when dry particles are used magnetic particle testing shall not be performed on the surface of parts whose temperature exceeds:

 
 
 
 

70.

According to ASTM E709-95 in using prod technique, prod spacing shall not exceed:

 
 
 
 

71.

According to ASTM E709-95, the UV intensity shall not be less than:

 
 
 
 

72.

According to ASTM E709-95 in using prod technique on a 50 mm thickness plate with a prod spacing of 101 mm (4 inches), current shall be selected in the following range:

 
 
 
 

73.

According to ASMT E709-95 alternating current electromagnetic yokes should give a lifting force of at least:

 
 
 
 

74.

According to ASTM E709-95 direct current electromagnetic yokes should have a lifting force of at least:

 
 
 
 

75.

According to ASTM E709-95 the UV light shall be centred on (1 Å = 10-10m):

 
 
 
 

76.

According to ASTM E709-95 when fluorescent particles are used, the UV light shall be above:

 
 
 
 

77.

According to ASTM E709-95 when fluorescent particles are used, the bulb shall be warmed up prior to use for at least:

 
 
 
 
 

78.

According to ASTM E709-95 with prod technique, the prods shall be tipped if the open circuit voltage is over:

 
 
 
 

79.

According to ASME Section VIII, a linear indication is defined as an indication in which the length is equal to or greater than the width by a factor of:

 
 
 
 

80.

According to ASTM E709-95 the viscosity limit (measured in cents Stokes) of the wet medium (conditioned water) should not exceed:

 
 
 
 

81.

According to ASTM E709-95 when applying fluorescent magnetic particles technique, the operator shall be in darkness area at least …………… prior to examination:

 
 
 
 

82.

According to ASTM E709-95 the alkalinity of conditioned water shall not exceed:

 
 
 
 

83.

According to ASTM E709-95, with wet continuous magnetization technique, the duration of magnetization current is of the order of:

 
 
 
 

84.

According to ASTM E709-95 in using prods having a spacing of 19 mm (3/4 inches) and above, the magnetizing current shall be:

 
 
 
 

85.

According to ASTM E709-95 powder shall be applied upon the part to be tested in such a manner that:

 
 
 
 

86.

According to ASTM E709-95 before turning off current and examination, dry powder in excess shall be:

 
 
 
 

87.

According to ASTM E709-95 demagnetization can be performed by:

 
 
 
 

88.

According to ASTM E709-95, Table 3., alternating current electromagnetic yokes must have a lifting force of at least:

 
 
 
 

89.

According to ASTM E709-95, Table 3., direct current electromagnetic yokes must have a lifting force of at least:

 
 
 
 

90.

According to API, the acceptable particle concentration of wet particle solution for fluorescent particles is:

 
 
 
 

91.

According to API, the particle concentration of wet particle solution must be checked:

 
 
 
 

92.

According to ASTM E709-95 and API, the UV intensity measured at a minimum of 38 cm (15 inches) at least shall not be less than:

 
 
 
 

93.

According to ASTME 709-95 and API, in order to eliminate all contaminants, an appropriate cleaning shall be performed on all the surfaces to be examined and on a minimum of adjacent material:

 
 
 
 

94.

According to ASTM E709-95 and API, the temperature of the dry particles can be used up to:

 
 
 
 

95.

According to ASTM E709-95 and API, the thickness of nonconductive coatings will not exceed:

 
 
 
 

96.

According to ASTM E709-95 and API, relevant indications are produced by:

 
 
 
 

97.

According to ASTM E709-95 and API, when fluorescent particles are used, the UV bulb shall warm-up prior to using for at least:

 
 
 
 

98.

According to AST M E709-95 and API, after removing magnetization of parts after examination, the residual magnetism shall not exceed (1 gauss = 0.0001 tesla):

 
 
 
 

99.

According to ASTM E709-95 and API, a linear indication is defined as an indication in which the length is equal to or greater than the width by a factor of:

 
 
 
 

100.

According to API, a non-relevant indication is defined as an indication which in the major dimension is equal to, or less than:

 
 
 
 

101.

According to ASME Section V, with fluorescent magnetic particles technique, the operator shall be in darkness area at least ……………. prior to examination:

 
 
 
 

102.

According to ASME Section VIII Div 1, Appendix 6, on pressure containing welds whose depth is greater than 15.8 mm (5/8 inches), which of the following indications is unacceptable:

 
 
 
 

Question 1 of 102

Are You Looking for Free NDT MT Level 2 Exam Practice Test?

Take A Free NDT MT Level 2 Exam Practice Test
Take A Free NDT MT Level 2 Exam Practice Test

If your answer is yes then you are at the right website. Here You Can Take a Free Online NDT MT Level 2 Exam Practice Test and Improve Your NDT MT Level II Magnetic-particle testing Exam Score. and Also Here You Can Learn everything you need to know about NDT MT Level II Exam.

We will help you to pass the NDT MT Level 2 Magnetic-particle testing Certification Exam in the first attempt —99% Guaranteed. Our expert-written NDT practice material covers the actual exam topics with fully explained answers.

Take unlimited free Quiz Course tests of any length. We have free new questions updated every week and you can study our material along with any other study materials.

If You Want to Buy Latest NDT MT Level II Magnetic-particle testing Exam Self Study Material, Please Feel Free to contact us.

Buy NDT MT Level 2 Exam Learning Package Study Material
IN EVERY 10 QUESTIONS 1 QUESTION COMES IN EXAM
WE HAVE LATEST NDT MT Level II Magnetic-particle testing Exam QUESTION BANK
Total 2000+ nos QUESTION BANK FROM THEORY TO PRACTICAL TO NUMERICALS.
Cost: $25.00
Email Us To Buy: upweld.org@gmail.com
Click Here To Contact On Whatsapp https://wa.link/4dn6ee
Ideally the only material needed for passing the examination. Free guideline during learning.
We give you a lot of additional study material Free of cost with this question bank..
Get BOTH Formats Instantly:
Online—Instant scoring, review & reporting.
Printable—Instant download.

If you want to get NDT MT Lavel II Training and Certification, Please feel free to contact us.